Proven Longevity. Predictable Performance. INGEVITY+ is built on the proven INGEVITY™ platform, with nearly 700,000 INGEVITY leads sold worldwide with a 99.2% survival at year 7. This active fixation pacing lead is designed for predictable performance.
Key features and technical specifications
Key features and technical specifications
•The INGEVITY MRI pacing lead family is backed with a lifetime warranty.*
The INGEVITY+ pacing leads are 6F (2.0 mm) steroid-eluting, endocardial pace / sense leads designed for permanent implantation for either atrial or ventricular applications.
INGEVITY+ is built on the proven INGEVITY platform, with nearly 700,000 INGEVITY leads sold worldwide with a 99.2% reliability at 7 years [1].
INGEVITY+ is specifically designed with three layers of insulation between conductors and a polyurethane lead body. The tri-filar inner coil design provides consistent, low, and repeatable turn counts when extending and retracting the helix [2].
These leads utilize an IS-1 bipolar connector. The tip features a flexible neck design and incorporates an IROX™ (iridium oxide) coating on the tip electrode.
Active Fixation Features
Extendable / Retractable Fixation: The extendable / retractable helix design anchors the distal tip electrode to the endocardial surface without support of trabecular structures, offering various lead placement possibilities for the tip electrode in the right atrium and / or right ventricle. The helix serves as the cathode for endocardial pacing and sensing. The lead is designed with a tri-filar inner coil for consistent and repeatable turn counts when extending and retracting the helix. The helix is extended and retracted using the fixation tool. Mapping: The lead helix is electrically conductive to allow mapping (measuring pacing and sensing thresholds) of potential electrode positions without extending the helix into the tissue. Mapping prior to lead fixation is recommended as it can reduce the potential need for multiple lead positioning. Fluoroscopic Markers: radiopaque markers near the distal tip can be seen under fluoroscopy. These markers show when the helix is fully retracted or fully extended.
* Limited lifetime warranty. For a full and complete description of the INGEVITY™ MRI family warranty - Please visit www.bostonscientific.com/warranty
1. Q3 2019 Boston Scientific Corporation Product Performance Report.
2. Internal data on file.